Measurements International’s new Temperature Resistance Standard 1310T is an easy-to-use automated resistance standard for temperature laboratories. The 1310T consists of 6 resistors and a connection for an external resistor, housed in a temperature-controlled chamber that utilizes a built-in 4-terminal scanner for optimal performance. The six resistor values 10 Ω, 25 Ω, 100 Ω, 200 Ω, 400 Ω and 1000 Ω, cover all of your temperature laboratory requirements. For customers who require even more, additional resistors can be added as a customized feature. Customers can now eliminate sources of error due to changing connections. Resistors are all housed in a temperature-controlled internal chamber eliminating the need for external temperature control.
Feature | Benefit |
6 resistors values 10 Ω, 25 Ω, 100 Ω, 200 Ω, 400 Ω and 1000 Ω. | One box covers all of your temperature measurement requirements. |
One box for all temperature lab application. |
Customers only need to buy one piece of equipment that contains all required standards. |
Unit has internal temperature chamber. | No external temperature chamber required, no external scanner required. |
Easy connection and change for resistors. | Customers do not need to re-wire connections as the unit has a built-in scanner board for automation and ease of use. |
Resistors based on proven resistor design with 24-hour stability of better than ± 0.01 μΩ/Ω. | Customers can achieve world-leading specifications in one cost-efficient solution. |
Built-in 4-terminal scanner. | Combining two instruments into one simple-to-use instrument. |
External extra channel. | Connect to the resistance value of your choice. |
Front panel or GPIB controlled. | Simplifies operation for the user. |
Internally mounted temperature sensor PT100. |
Users can connect to the front panel and monitor the internal oven. |
Nominal Resistance (Ω) |
Tolerance (± μΩ/Ω) (± ppm) |
24-Hour Stability (± μΩ/Ω) (± ppm) |
12-Month Stability (± μΩ/Ω) (± ppm) |
Temperature Coefficient (± μΩ/Ω/°C) (± ppm/°C) |
Max. Voltage (Volts) |
10 | 10 | 0.01 | 2.5 | 0.005 | 1.0 |
25 | 10 | 0.01 | 2.5 | 0.005 | 1.58 |
100 | 10 | 0.01 | 2.5 | 0.005 | 3.16 |
200 | 10 | 0.01 | 2.5 | 0.005 | 4.47 |
400 | 10 | 0.01 | 2.5 | 0.005 | 6.32 |
1000 | 10 | 0.01 | 2.5 | 0.005 | 10.0 |
Internal Temperature Stability | ± 0.1 °C Over a 1-Year Period | ||||
Ambient Temperature Range | 23 °C ± 5 °C | ||||
Ambient Humidity Range | 20 to 70 % RH | ||||
Warranty | Standard 2-Year Parts & Labour |
Scanner Specifications
Operation | Four-Terminal |
Error Contribution | < 20 nV |
Contact Configuration | Relay – Two Coil Latching |
Max Carrying/Switching Current | 4/2 A @ < 30 V (DC) |
Maximum Working/Switching Voltage | 1000/220 V @ < 100 mA (DC) |
Contact Resistance | < 0.05 Ω |
Expected Relay Life | 108 Operations |
Insulation Resistance | > 1012 Ω |