2701A

2701A Transconductance Amplifier

  • 0 to 100 Amps – AC
  • 0 to ±100 Amps – DC
  • Voltage Compliance ±5 Volts
  • IEEE488 Interface
  • Resistive, Capacitive, Inductive Loads
2600A

2600A AC Transimpedance Amplifier

  • Current to Voltage
  • 2 Outputs of 10 & 1 VAC
  • Loss Measurement Systems
  • Current Transformer Calibration
  • IEEE488 Interface
  • Uncertainty to ≤20ppm
  • Calibration Period 3 to 5 Years
6800C System

6800C QHR Standard

  • Cryogen Free
  • System Accuracy to <0.02ppm
  • Built in Rxx (uVolt) Measurements in ADCC Bridge
  • Built in Rxx (nVolt) Measurements in ADCC Bridge
  • 9 Tesla Standard System Magnet
  • Up to 14 Tesla Available
  • No Liquid Helium Required
  • Stable Controlled Sample Environment
  • Temperature Range 1.3K to 300K
  • Low Operating Costs
  • Direct Transfer to 1kΩ and 10kΩ Standards
  • System Range 0.1Ω to 100kΩ
  • Graphene Compatible
  • Features Accubridge Technology
  • Dual Sample Probe
GPIB Meter

GPIB/USB Interface Cable

The GPIB‑USB‑HS is an IEEE 488 controller device for computers with USB slots. The GPIB‑USB‑HS achieves maximum IEEE 488.2 performance. With no GPIB cable required for instrument connection, you can use the hi‑speed USB port to control up to 14 programmable GPIB instruments. This device is completely IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

7070A

7070A-UI AC Ratio Bridge

  • Calibration of Voltage and Current Transformers from a Single Instrument
  • Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard
  • Calibration of Voltage Transformers (VT) Up to 800kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors
  • Calibration of Current Transformers (CT) Up to 10000A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators
  • Short Measurement Times with High Accuracy and Low Inherent Burdens
  • Instrument Applications are Valid for Single Phase Measurements. Three Phase Transformers Measurements Performed by Testing Each Phase Separately
  • Test Frequency from 15 to 100 Hz
7070A

7070A-U AC Voltage Ratio Bridge

  • Calibration of Voltage Transformers
  • Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard
  • Calibration of Voltage Transformers (VT) Up to 800kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors
  • Short Measurement Times with High Accuracy and Low Inherent Burdens
  • Instrument Applications are Valid for Single Phase Measurements. Three Phase Transformers Measurements Performed by Testing Each Phase Separately
  • Test Frequency from 15 to 100 Hz