Measurements International continues to focus on Research & Development in order to provide customers with the most leading edge technology. Below you will find the most recent releases from MI. Metrology is our Science, Accuracy is our BusinessTM

6800C QHR Standard

6800C QHR System

6800C QHR Standard –

  • Cryogen Free
  • System Accuracy to < 0.02 ppm
  • Built in Rxx (uVolt) Measurements in ADCC Bridge
  • Built in Rxx (nVolt) Measurements in ADCC Bridge
  • 9 Tesla Standard System Magnet
  • Up to 14 Tesla Available
  • No Liquid Helium Required
  • Stable Controlled Sample Environment
  • Temperature Range 1.3 K to 300 K
  • Low Operating Costs
  • Direct Transfer to 1 kΩ and 10 kΩ Standards
  • System Range 0.1 Ω to 100 kΩ
  • Graphene Compatible
  • Features Accubridge Technology
  • Dual Sample Probe

Data Sheet: 6800C QHR Standard

2023A Series 3-Phase Power Analyzer

Model 2023A Three Phase Power Analyzer using new Digital Sampling Technology

3-Phase Power Analyzer –

  • Basic Power Accuracy < 0.005 %
  • 5 A Current Input with 10 Current Ranges
  • 240 V/120 V Voltage Input Ranges
  • Line-to-Neutral and Line-to-Line Voltage Measurements
  • Full Power Factor Range
  • Total Harmonic Distortion Analysis
  • Complete Waveform Analysis
  • Phasor Analytical Representation
  • Single-Phase/Three-Phase Series of Wattmeter/Power Analyzers

Data Sheet: 2023A 3-Phase Power Analyzer

2020A Power Analyzer

2020A Wattmeter

2020A Power Analyzer –

  • Basic Power Accuracy < 0.005 %
  • 5 A Current Input with 10 Current Ranges
  • 240 V/120 V Voltage Input Ranges
  • Line-to-Neutral and Line-to-Line Voltage Measurements
  • Full Power Factor Range
  • Total Harmonic Distortion Analysis
  • Complete Waveform Analysis
  • Phasor Analytical Representation
  • Single-Phase/Three-Phase Series of Wattmeter/Power Analyzers

Data Sheet: 2020A Power Analyzer

7070A Series of Ratio Bridges

7070A

7070A Series of Ratio Bridges –

  • Calibration of Voltage and Current Transformers from a Single Instrument
  • Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard
  • Calibration of Voltage Transformers (VT) Up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors
  • Calibration of Current Transformers (CT) Up to 10,000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators
  • Short Measurement Times with High Accuracy and Low Inherent Burdens
  • Instrument Applications are Valid for Single Phase Measurements. Three Phase Transformers Measurements Performed by Testing Each Phase Separately
  • Test Frequency from 15 to 100 Hz

Data Sheet: 7070A Ratio Bridges

9300L Air Bath

9300L - Measurements International

9300L Air Bath –

  • Temperature Range: +15 °C to +50 °C
  • Refined Solution for Ultra-Stable Temperature Environment 24/7, 365
  • Stability ± 0.005 at 23 °C
  • Dry, Clean, Stable, Silent, Storage for Standard Resistors
  • Perfect for Temperature Coefficient Measurements
  • Peltier Cooled
  • Fast Heating/Cooling Rate
  • Keeping the Temperature Within 10 mK Over Days
  • Cascade PID Control
  • Side Access Ports for Cables & Probes
  • Volume 190 Litres
  • Stainless Steel Construction

Data Sheet: 9300L Air Bath

9300S Air Bath

9300S - Measurements International

9300S Air Bath –

  • Volume 53 Litres
  • Temperature Range +15 °C to 50 °C
  • Stability ± 0.005 @ 23 °C
  • Peltier Cooled
  • Fast Heating/Cooling Rate
  • Stainless Steel Construction
  • Perfect for Temperature Coefficient Measurements
  • Refined Solution for Ultra-stable Temperature Environment 24/7, 365
  • Dry, Clean, Stable, Silent, Storage for Standard Resistors
  • Keeping the Temperature Within 10 mK Over Days
  • Cascade PID Control
  • Side Access Ports for Cables & Probes

Data Sheet: 9300S Air Bath