6011 Series of Range Extenders

• Modular designed base unit with expanded
capabilities to 3000 Amps.
• Ampere Turn Sensitivity = 2uAT = 0.02 ppm
• Precision Shunts and DCCT Calibrations
• Stand alone operation or extends the range of
the 6010/6242 Series of Resistance Bridges
• 6100 Series of High Current Linear Supplies
• Bench top or Rack Mount
• Your partner in ISO 17025 accreditation through
coaching, system design & implementation,
calibration services and ongoing expert
support.

Features & Benefits

Since its introduction in 1993, the 6011 series of range extenders has earned a worldwide reputation for performance, dependability and quality, and as a result it is the range extender of choice for electrical calibration throughout government and industry. The model 6011 uses the ratio of two windings on a DC Current Comparator (DCC) to measure the ratio of two currents. The 6011 series of products are used to divide high currents down to workable levels. Measurements International is the only commercial laboratory that can provide accredited ratio calibrations to 0.2 ppm

Today, the 6011 series of range extenders offer even more. In addition to dependability, simplified calibration, easeof-use, automation and worldwide support, the 6011 is the BEST and ONLY Range Extender that offers complete automation with uncertainty specifications that rival anything available on the market today. Customers can get all the performance they need to calibrate their most demanding workload. Typical applications are shown below for current source calibration using the 6511D with it built in current source to 10A (Fig 1) and the 6011D with an external current source, Model 6150, (Fig 2).

6150_Image                                   6511_Image

The 6011 Series of Range Extenders are also used to extend the range of the worlds number one resistance bridge, the MI 6010 or 6242 for calibrating shunts and DCCTs with better accuracy as compared to using a DMM. This new series of Range Extenders provide customers with flexibility in cost at the highest precision available on the market today. These are real solutions that address both current and future workload solutions while addressing the ever tightening budget constraints.

At MIL, it’s not only about the equipment or the science…. It’s about what that will enable
YOU
to do, and the ease with which you can do it.

There are several models available including the 6511D/10, 6011D/150, 6011D/200 and 6011D/300. As a stand-alone unit the 6011D has front panel push buttons for selecting the ranges and reversing the current or it can be controlled using the IEEE488 Interface Bus. Current ranges can be selected by pressing the 10, 100 or 1000 ratio keys. Each model has a built in reversing switch which can be reversed by pressing the Normal/Reverse key.

The precision DCC in the and 6011D uses a two-core magnetic modulation technique in a feedback loop to generate a secondary current. This secondary current is further modified by a circuit, which monitors the primary current and the turn’s ratio of the comparator toroid. Together, these two circuits create an effective loop gain in excess of 107 which forces the secondary ampereturns to be equal the primary ampere-turns to better than 0.02 ppm, thus, making the instrument act as a precision DC Current Transformer. Offsets and thermals of the DCC are removed by reversing the Ix current. All connections to the 6511 and 6011 series of range extenders are made on the rear panel.

The Ix and Rx connectors have full current inputs (150A/300A) as well as 30A inputs. This means that if you are using the 6011D at currents below 30A it is not necessary to use the high current cables.

Calibration of the 6011D

The 6011D is a ratio device, the ratio being determined by Nx/Ns where Nx =1, 10 or 100 turns and Ns = 1000 turns for ratios of 1000, 100 and 10. A ratio calibration technique is used to calibrate the 6011D using the stable ratio of standard resistors and the 6010 or 6242 resistance bridge as the reference.

A single output for the range extender is located on the rear panel. For current source calibration a standard resistor between 1 ohm and 100 ohm (Fig. 1 and 2) can be connected across the output where a DMM can be used to read the voltage across the resistor. A Measurements International Series 6150 (150A) or 6250 (300A) power supply can be supplied in a rack with the 6011D/150 or 6011D/300. The drivers for the Keysight series of 6600 current sources are also included in the MI supplied software.

The input and output currents for the 6011D are shown in the Specification Table. Full-scale output current of the 6011D/150 is 100 mA on Range 10 and 100 and 150mA on Range 1000. Full scale output current for the 6011D/200 and 6011D/300 is 100 mA on all ranges.

For complete automation of several 30A shunts see our 20 channel
4220/30 four terminal 30A matrix scanner.

6011D Range Extender Applications

Shunt calibration or DCCT calibration can be performed using two precision DMM’s to compare the shunt or DCCT output voltage with the voltage across the standard resistor (Fig 4 and Fig 5). Automated software can be supplied (Model 6300) to configure the system for automated Shunt and DCCT measurements up to 3000 Amps. For more accuracy the 6010 or 6242 may also be used in place of the DMM’s to calibrate shunts and DCCTs as shown in Figure 6 & Figure 7.

 figure 5

 The 6511D Range Extender and the 6011D Range Extender (Figure 7) may also be used in conjunction with MI’s Model 6010D or 6242D Resistance Bridges and the MI 6150A (max 150A) and 6250 (Max 300A) Power Supplies or the Keysight Technologies 6600 series of DC Power Supplies.

3000A_6010

DCCT

Specifications

Please see data sheet for specifications

Information Request

  • Please fill in the details below to receive more information on this product

    * = Required Fields