Model 2023A-XP – 3-Phase Power Analyzer

  • Extended Performance for Full Power Analysis
  • Total Harmonic Distortion Waveforms
  • Complete Waveform Analysis
  • Phasor Analytical Representation
  • Best Accuracy <0.0025%
  • Basic Power Accuracy <0.005%
  • 5A Current Input with 10 Current Ranges
  • 240V/120V Voltage Input
  • Line and Line to Line Voltage Measurements
  • Full Power Factor Range
  • Distorted Waveforms
Features & Benefits

The new 3-phase version Model 2023A is offered in two different versions also.  A 3-phase wattmeter 2023A, or the Model 2023A-XP version power analyzer.  The 2023A-XP is a 3-phase power analyzer that has the additional features of total harmonic distortion analysis, complete waveform analysis and phasor analytical representation.

A large touch screen display is used to change the input parameters and for indicating the voltage, current and power measurements simultaneously. Waveforms of the input voltage and current can also be displayed and saved to a USB stick on the front panel or transferred to a computer over the LAN. An Rs232 interface is standard and an optional IEEE-GPIB card is available. With the IEEE Card only the Voltage, Current and Power values can be transferred. Waveform data is transferred over the LAN.

The 2020A/2023A can be used to measure line to ground and line to line voltage measurements that are 120° apart with one current input. The current input is a two-stage-compensated current-transformer with 10 current ranges from 5A down to 5 mA, the voltage input consists of an accurate voltage divider with 120V and 240V ranges.

The displayed output for power is expressed as VI Cosɸ. The measurement high accuracy’s is maintained for all power factors. The relative conversion error of the output is linear and does not depend on the magnitude or distortion of the input signals.

Specifications
Model No. 2020A
Single-Phase
2020A-XP
Single-Phase
2023A
Three-Phase
2023A-XP
Three-Phase
Input Channels 2 Voltage +
1 Current
2 Voltage +
1 Current
3 Voltage + 3I 3 Voltage + 3I
Application Wattmeter Power Analyzer Wattmeter Power Analyzer
Voltage
120 Volt Yes Yes Yes Yes
Accuracy (ppm) ±25 ±25 ±25 ±25
Linearity (ppm) ≤20 ≤20 ≤20 ≤20
Input Impedance (Ω) 500k 500k 500k 500k
Frequency (Hz) 12 to 400 12 to 400 12 to 400 12 to 400
240 Volt Yes Yes Yes Yes
Accuracy (ppm) ±25 ±25 ±25 ±25
Linearity (ppm) ≤20 ≤20 ≤20 ≤20
Input Impedance (Ω) 1M 1M 1M 1M
Frequency (Hz) 12 to 400 12 to 400 12 to 400 12 to 400
Current Measurement
Ranges (A) 0.005, 0.01, 0.02, 0.05, 1, 2, 5 0.005, 0.01, 0.02,
0.05, 1, 2, 5
0.005, 0.01, 0.02,
0.05, 1, 2, 5
0.005, 0.01, 0.02, 0.05, 1, 2, 5
Accuracy (ppm) ±25 ±25 ±25 ±25
Linearity (ppm) ≤20 ≤20 ≤20 ≤20
Input Impedance (Ω) 3.5 3.5 3.5 3.5
Isolation (Vpp) 600 600 600 600
Frequency (Hz) 12 to 400 12 to 400 12 to 400 12 to 400
Power Measurement
Power Factor
0 to 0.5 >0.5
0 to 0.5 >0.5
0 to 0.5 >0.5
0 to 0.5 >0.5
Line to GND Accuracy (ppm)
±25 ±50
±25 ±50
±25 ±50
±25 ±75
Line to Line Accuracy (ppm)
±25 ±75
±35 ±75
±35 ±75
±35 ±75
Linearity (ppm) ≤20 ≤20 ≤20 ≤20
Harmonic Distortions
Measurement
No Yes No Yes
Complete Waveform Analysis No Yes No Yes
Phasor Analysis No Yes No Yes
Operating Environment
Temperature (Celcius) 15 to 40 15 to 40 15 to 40 15 to 40
Relative Humidity 10 to 80
Non Condensing
10 to 80
Non Condensing
10 to 80
Non Condensing
10 to 80
Non Condensing
Line Voltage
Voltage (V) 100 to 240 100 to 240 100 to 240 100 to 240
Frequency (Hz) 47 to 63 47 to 63 47 to 63 47 to 63
Dimensions 480 x 585 x 175 (mm) 480 x 585 x 175 (mm) 480 x 585 x 235 (mm) 480 x 585 x 235 (mm)
Weight 15 kg 15 kg 28 kg 28 kg