2701A

2701A Transconductance Amplifier

  • 0 to 100 Amps – AC
  • 0 to ± 100 Amps – DC
  • Voltage Compliance ± 5 Volts
  • IEEE-488 Interface
  • Resistive, Capacitive, Inductive Loads
2600A

2600A AC Transimpedance Amplifier

  • Current to Voltage
  • 2 Outputs of 10 & 1 Vac
  • Loss Measurement Systems
  • Current Transformer Calibration
  • IEEE-488 Interface
  • Uncertainty to ≤ 20 ppm
  • Calibration Period 3 to 5 Years
6800C System

6800C QHR Standard

  • Cryogen Free
  • System Accuracy to < 0.02 ppm
  • Built in Rxx (uVolt) Measurements in ADCC Bridge
  • Built in Rxx (nVolt) Measurements in ADCC Bridge
  • 9 Tesla Standard System Magnet
  • Up to 14 Tesla Available
  • No Liquid Helium Required
  • Stable Controlled Sample Environment
  • Temperature Range 1.3 K to 300 K
  • Low Operating Costs
  • Direct Transfer to 1 kΩ and 10 kΩ Standards
  • System Range 0.1 Ω to 100 kΩ
  • Graphene Compatible
  • Features Accubridge® Technology
  • Dual Sample Probe
GPIB Meter

GPIB/USB Interface Cable

The GPIB‑USB‑HS is an IEEE-488 controller device for computers with USB slots. The GPIB‑USB‑HS achieves maximum IEEE-488 performance. With no GPIB cable required for instrument connection, you can use the hi‑speed USB port to control up to 14 programmable GPIB instruments. This device is completely IEEE-488 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

7070A

7070A-UI AC Ratio Bridge

  • Calibration of Voltage and Current Transformers from a Single Instrument
  • Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard
  • Calibration of Voltage Transformers (VT) Up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors
  • Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators
  • Short Measurement Times with High Accuracy and Low Inherent Burdens
  • Instrument Applications are Valid for Single Phase Measurements. Three Phase Transformers Measurements Performed by Testing Each Phase Separately
  • Test Frequency from 15 to 100 Hz
7070A

7070A-U AC Voltage Ratio Bridge

  • Calibration of Voltage Transformers
  • Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard
  • Calibration of Voltage Transformers (VT) Up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors
  • Short Measurement Times with High Accuracy and Low Inherent Burdens
  • Instrument Applications are Valid for Single Phase Measurements. Three Phase Transformers Measurements Performed by Testing Each Phase Separately
  • Test Frequency from 15 to 100 Hz